Part No. 600PEM
600 Electrolyzer Test System (ETS) ระบบทดสอบ PEM Water Electrolysis แบบตั้งโต๊ะ รวม Power Supply, Potentiostat, Impedance Analyzer (EIS/HFR) และเซนเซอร์ Real-time สำหรับงานวิจัยและวิเคราะห์เซลล์อย่างแม่นยำและปลอดภัย
The 600 Electrolyzer Test System (ETS) is a next-generation, high-performance bench-top test system engineered for in-depth research and development of Proton Exchange Membrane (PEM) water electrolysis. This all-in-one solution delivers unmatched precision, control, and safety for the diagnostic evaluation a single electrolysis cell.
Equipped with a fully integrated Power Supply, Potentiostat, and Impedance Analyzer (supporting both EIS and HFR), the 600 ETS also features real-time sensors for Product Flow Rate and Cross-over Monitoring, providing researchers with critical insights at every stage of testing.
ADVANCED FEATURES
Unlock powerful capabilities designed to simplify complex testing. From automated fluid handling to seamless data connections, every feature is built for efficiency, accuracy, and ease of use:
• Integrated 100A Power Supply with EIS & HFR – Seamlessly combine electrochemical impedance spectroscopy (EIS) and high-frequency resistance (HFR) for comprehensive insights.
• Half Cell (R1/R2) Measurements in Power Supply Mode – Get accurate data effortlessly. Our system simplifies half-cell measurements.
• Dual Channel Mass-Flow Controller (MFC) – Say goodbye to manual rotometers! Our MFC ensures precise gas flow control, with automated safety interventions.
• Streamlined Cell Cabling – We’ve redesigned the front panel for a simpler, more efficient cabling arrangement.
• Single USB Connection – Connect effortlessly. One cable, one clear bench.
• Automated Tank Refill – Unattended operation for electrolyte experiments is now a reality. Let our system handle the details.
• DI Water Conductivity Probes – Monitor conductivity inside the feed tank via front panel displays and collect data in our FlowCell software.
• Self-Draining Condensation Tanks – Boost automation and reduce maintenance. No more manual draining.
| Specifications | |
| Electrical | |
| Power Supply Max Current | 100A |
| Voltage Range | 0-5.000V DC |
| Maximum Power | 500W |
| Potentiostat Current Ranges | ±20 / 7 / 0.7 / 0.07A |
| Current Resolution | 0.007% of range |
| Current Limit of Error | ±1.0% of range |
| Set & Read Voltage | >±5.000V |
| Cell Voltage Sense Lead | Differential |
| Sense Lead Input Resistance | 1.0GΩ |
| Modes of Operation | Constant, Scan, Step-Stair; V and I |
| Impedance Frequency Range | 1 mHz to 10 kHz |
| Impedance Measurement Types | Sweep EIS and Single-Freq HFR Real-Time Measurement, Whole Cell and Aux |
| Cell & Electrolyte Handling | |
| Flow Path | All 316SS |
| Liquid Feed Tank | 1x 2L, Auto Fill |
| Liquid Feed Concentration | In situ DI Water Conductivity |
| Liquid Feed Flow | 50-700 mL/min |
| Liquid Feed Temp | Ambient – 95ºC |
| Liquid Filtration | In-line De-Ionized Recycling Loop |
| Back Pressure | Dual, 0-2 bar g (0 – 30 psig), Manual |
| Purge Gas | 2x 0.5 SLPM N2 MFC |
| Water/Gas Separation | 2x Auto-Draining Condensers |
| Product Mass Flow Measurement | 1 SLPM H2 & O.5 SLPM O2 |
| Additional Data Acquisition | 7 Temp & 7 Analog (0-5V, 4-20mA) |
| Cell Temperature | Ambient – 125ºC |
| Cell Connection | 4-Terminal (I+,I-,V+,V-) & Differential Aux (REF) |
| Physical | |
| Operating Temperature | 5-35º C |
| Power Source | 100-120 or 220-240 VAC 50/60 Hz |
| Size (excluding tubing connections) | 53 cm x 53 cm x 100 cm (21 x 21 x 39.5 in) |
| Weight (empty) | 45 kg (100 lbs) |
| Safety | |
| Robust | Embedded Firmware Level Decisions |
| Fail Safe Design | N2 Purge On Alarm Condition |
| Continuous Monitoring | E-Stop, Voltage, Current, Temperate, Gas, Contamination & External Signals |
ขนาด 700 ลิตร (24 คิว) ช่วงการควบคุมอุณหภูมิ 2-8 °C ตู้ 2 ประตู กระจกใส 2 ชั้นป้องกันไอน้ำเกาะที่กระจก ส่งสัญญาณเสียงเตือน เมื่อค่าอุณหภูมิเกินค่าที่ตั้งไว้
ห้องทดสอบความเสถียรแบบคอนเทนเนอร์ที่พัฒนาต่อยอดจากเทคโนโลยี Walk-in Stability Rooms ออกแบบเป็นระบบสำเร็จรูปแบบเคลื่อนย้ายได้ ติดตั้งได้ทั้งภายในอาคารและภายนอกอาคาร ขนาด 20 และ 40 ฟุต ความจุสูงสุด 40,000 ลิตร
ตู้สำหรับการทดสอบความเสถียรของผลิตภัณฑ์ในอุตสาหกรรมยา เครื่องสำอาง อาหารเสริม และชีวเภสัชภัณฑ์ มีขนาด 600 ลิตร และ 1200 ลิตร ถูกออกแบบมาเพื่อรองรับการทดสอบตามมาตรฐาน ICH Q1A อย่างแม่นยำ
ห้องเพาะเลี้ยงพืชออกแบบมาเพื่อการผลิตพืชทางการแพทย์ สามารถควบคุมสภาพแวดล้อมได้อย่างละเอียด เพิ่มผลผลิตและคุณภาพของพืชตั้งแต่ระยะเริ่มต้นจนถึงการเก็บเกี่ยว ควบคุมอุณหภูมิ 5°C ถึง 45°C ระบบแสงสูงสุด >2000 µmol/m²/s
บริษัท เอ็นเทค อินดัสเทรียล โซลูชั่น จำกัด
17/121 ซอยงามวงศ์วาน 47 แยก 48 แขวงทุ่งสองห้อง
เขตหลักสี่ กรุงเทพฯ 10210
กรุณาระบุจำนวนสินค้าที่คุณต้องการ แล้วกดปุ่มด้านล่าง
จำนวน
กรุณาทำการลงทะเบียนเพื่อเป็นสมาชิก โดยสมาชิกสามารถดาวน์โหลดคู่มือการใช้งาน